woWolof

Circuit yu gàtt ci batëri chariot élévateur: lu ko waral, aar ak saytu ci tool bi

Aug 25, 2026

Bayil ab bataaxal

Batëri chariot élévateur dafay am court-circuit buñu bëggul woon ci pack bi, te ci sistem motif bu 48 V, courant biy waaja am dafay wàcci diggante 5,000 A ak 10,000 A - lu doy ngir souder benn conector ci diir bu gàtt. Ndax loolu mooy mujjee ci fuse bu raxas wala camion bu yàqu, mingi aju ci benn mbir: ñaata couche de protection ñoo toog ci diggante selul yi ak fault bi, ak ni bu nekk ci ñoom di gaawe.

Li ci topp dañu ko bind ngir nit ñiy woote ci etaasu atelier bi wala ci xoolaat leeral yi. Ohm's Law ñu ngi ko wax benn yoon ginaaw ga nu dem.

Fan la Fault Path toog: Bitti vs Biir

 

Laaj bi gëna am njariñ ginaaw njuumte duLu taxwaayefan. Barab bi mooy wane li dindi jafe-jafe bi, ba ñaata fan la pack bi tëjoo, ak ndax amna luñu mëna defar.

 

Barabu njuumte Déclencheur tipikal Lu koy leer Jamonoy fomp Yaxxum yi des
Terminal wala lëkkalekaay buñ boole ci biti Clé bu daanu, boîtier conecteur bu yàqu, mbalitu wen ci biir ndab li Fuse DC bu mag Sub-milisegond ci courant bu bari pitting bu laal; mën nañu wecci lëkkalekaay bi
Fiil kuuraŋ bi dafa laxasu ci tegukaay bi wala ci kaadaru kamioŋ bi Vibration ci kaw benn boor buñu tëjuwul ci kaw téemeeri coppite Fuse DC, yenn saa yi fuse contrôleur camion bi mooy njëkka Sub-milisegond ba ay milisegond yu néew scrap section Harnais; Saytu isolation bu tegukaay bi
Busbar-ba-isolation boîtier Duggug raxas, siklu kondensasioŋ ci dencukaay bu sedd Fuse DC; BMS mën nako bind ni courant bu ëpp Milisegond Busbar ak standoff wuutu; dindi pack
Aparey biy soppiku (MOSFET wala kontaktër buñ soudé tëju) Dagg yu bari ci wetu note, rebond contact ci suufu sargal DC fuse rek - aparey bi defoon mënul fomp boppam Sub-milisegond Wecci module wala kontaktër; xoolaat koordinaasioŋ bi
Selul-separatër bi ci biir Yaxxute ci mbëkk, plaking bu bawoo ci sarse bu sedd, sikk bu nëbbu ci selil bi Amul lenn lu nekk ci biti - njuumte bi mingi ci biir selil bi Duñu ko mëna jëfandikoo Selul ak module yu bari; risku xew-xewu tàngoor

 

Liggéey bu mujj bi moo gëna am solo te kenn duko bàyyi xel lool. Fault externe mooy xew-xew bi am ndoorte ak njeexte. ab short interne mooydoxalin yu xel nàngu: ab yoonu -bañ bu kawe mooy njëkka forme, self-decharge dafay yéeg, benn selil dafay dem ci dëkkandoo yi, ginaaw ga bañ bi dafay daanu. Sudee benn selil ci benn modle toog 20–40 mV ci suufu pack moyenne ci noppalukaay ba noppi gap bi di gëna yaatu ayu-bis ci ayu-bis, loolu mooy siife bi jara gëstu - du alarm bu dramatik.

 

External short circuit fault path across forklift battery terminals and busbars

 

Jiroom benn Yooni Fallu yuy Teg Motif Packs ci Risk

 

Loolu mooy liy faral di am ci liggéeyu yoriinu macceer. Ku nekk ci ñoom amna matuwaay buy dindi li waral feebar bi te du dindi li ko waral.

 

1. Ci suufu-busbar bu am couple wala bu loose ak jointing borne yi.Jumtukaay bu yeex-, du juumte ci saasi. Joint bu yegg ba 0.5 mΩ bi muy yab 200 A dafay dindi 20 W ci lug bu tollu ni baraam; përëm bi dafay anneal, barabu jokkool bi dafay wàññeeku, bañaale bi dafay yokk, ba noppi cycle bi dafay gaaw ba pont yi arc dem ci potentiel bi ci wetam. Cifre yiñ siiwal ci couple biñ siiwal ci M8 copper busbar joints dañuy faral di toog ci 10–15 N·m band - waaye jëfandikoo valeur bi defarkatu pack bi wax, ba noppi re{10}}couple ginaaw 50 waxtu liggéey yu njëkk yi balaa ñuy dugg ci ab diggante at.

 

2. Fiil bi dafa yàqu ndax yëngu.Plaque de dock ak joint expansion yi deñuy dugal yëngu-yëngu bu am ampilitude bu woyof ci biir harnais bi. Sudee fiil bi dafa jàll ci catu ndab bi te amul benn manche abrasion wala pince bu takku ci diggante 300 mm ak fi mu jàkkarloo, jàppee ko ni ab panne buñ waajal moo gën nga jàppee ko ni lu mëna am.

 

3. Ndox ak contamination conducteur.Aar Ingress mooy leeral yi ñuy joxe ci quoting ak mbir yi ci serwiis bi. Pack IP54 du mucc ci pënd ak ci ndox mi; du muñ ab presioŋ -washer, wala kondensasioŋ bu kamioŋ buy daw diggante −25 degre ak ambient lu bari yoon ci turnu bu nekk. Fàww raxas dafa bokk ci liggéey bi, IP65 ci boîtier bi ak IP67 ci interfaasu konektër bi mooy dër bi dëgg.

 

4. Konektër bi mënul méngoo ak njuumte ci polarite bi ci barabu sarse bi.Ci sit yi am voltage yu wuute -, résultat bu jaar yoon ci soppi fase - yaram yu nuróo ci 24 V, 36 V ak 48 V ci sircuit yi, mën nañu jur loraange dëgg. Caabi mekanik wala kodage melo ci klaas voltage bu nekk daanaka amul benn njëg te dina dindi mode de défaillance.

 

5. Sarse ci suufu tàngoor wi selil bi may.Sarse benn selil LiFePO4 ci suufu lu tollu ci 0 degre plate litium metalik ci kaw anode bi ci barabu ko boole. Deposit yi dañuy cumulatif te kenn gisu leen, te ñooy yoon wi gëna mag bi selil-fault interne di màggee ci pack buñu musul jëfandikoo mekanik. Bépp pack buñ nara def ci dencukaay bu sedd mingi soxla chauffage bu mat sëkk wala BMS buy tere - sarse ci suufu threshold biñ wax - mesaasu àrtu nekkul seytu.

 

6. Impact mekanik bi ñuy jëfandikoo ndab ak weccoo pack.Extraction ci wet yi ak lift yi ci kaw dañuy def ay sargu point ci koñu enclos yi. Loraange yi dañuy faral di nëbbu: dara du am ci bis bi, ba noppi benn njuumte dafay feeñ ginaaw ga ndax separatër biñ yàq dafa mujjee ñàkk. Bépp pack bu am impact buñ enregistre dañu ko wara bind, génne ko ci pool swap bi, ba noppi xool ndax self-decharge laata muy dellusi ci rotation.

 

Caden de protection ak ni layer bu nekk di gaawe

 

"Aar ci sircuit bu gàtt buñ tabax" dafay feeñ ci fiche de données bu nekk ci batëri chariot élévateur litium te amul benn njariñ ci boppam. Li am solo mooy ban diisaay la am, lan lañu jox bu nekk ci ñoom poñ, ak ci ni ñuy doxee.

 

Lal Fonction ci suufu fault bu dëgër Jamonoy tontu buñ miin (xoolal ci këyitu done yi) Njëg ngir firnde
Niveau CID / PTC Dakkal wala tënk courant bi ci biir selil bi Pression- wala tàngoor-dawal; du determinist Dafay faral di ñàkk ci selul LFP prismatik yu mag yi - bul jàpp ni mingi fa
gis-gis ab sircuit bu gàtt ci aparey BMS Dafay santaane etapu coppite bi ubbeeku ci threshold bi fi nekk, moom boppam ci losisel bi 100–500 μs lañuy siiwal Limite ci ampere, ak ndax dafay méngale aparey bi wala loop losisel bi
Kontaktër bu mag Dafay xàjjale pack bi -ci kanamcourant defaut bi jeexna Serpentin-ba-ubbeeku 10–30 ms Defar/dog note, bi toog fu sori ci suufu courant de fault prospective
Fuse DC bu mag Benn aparey bi mëna dagg benn njuumte bu magnitude - bu mat Sub-milisegond ci courant bu bari Kàttanu dindi ci kA ci voltage DC bi ci pack bi, boole ci dindi I2t
Regulatëru kamioŋ / fuse auxiliaire Aar wetu oto bi, du pack bi Milisegond Koordinasioŋ ak fuse bu mag bi suko defee aparey bi war di njëkka ubbeeku

 

Liggéey bi gëna yàq tool bi mooy contacteur bi. Kontaktër ab aparey la buy wecci charge-, du ab dakkal njuumte. Sudee pack 48 V dafa am fault ci 8 kA te contacteur bi ubbeeku ci arc bi, contact yi dañuy souder - ak contacteur buñ soudé dafay tekki ni pack bi mënul isoler ci ganaw. Koordinaasioŋ bu jaar yoon fàww fuse bi njëkka leer, contacteur bi ubbeeku ci sircuit bu jota dee. Kon laaj bi nga wara laaj furnisër bi mooy "ndax amna kaaraange ci sircuit bu gàtt" waaye "lan mooy kàttan gi fuse bi mëna dog ci voltage DC bi, te ndax mingi ci kaw courant bi ñu xayma".

 

Pack yiñ tabax ci architecture bu am ñeenti-layer leegi dañuy nekk standard ci -ci jamono jiiLiFePO4 chariot élévateur électrique batëri ak aar buñ boole, waaye limu layer yi kese duñu la wax dara - ci note yi. Gis-gis bi benn la ci liggéey yiñ wara def fii;lu BMS chariot élévateur def lu weesu gis ay njuumtedafay muur wàllu ekilibre, logging ak jokkoo.

 

Protection layers between cells and a fault in a lithium forklift battery pack

 

Plomb-Acid vs LiFePO4: Lan mooy soppiku ci njuumte ci boppam

 

Taabal bii dafa sew Dafay méngale - doxalinu sircuit bu gàtt - du njëg, diir bi ñuy doxalee wala pexem sarse, ñoom ñaar ay dogal yu wuute lañu ak ay firnde yu wuute. Soppi benn flot du dindi risku sircuit bu gàtt; daf koy toxal, ba noppi di soppi wàll yi ci toppatoo bi wara am seen palaas.

 

Moomeel plomb -batëri motër asid LiFePO4
Modu njuumte bi gëna am solo ci biir Separatër bi dafa yàqu, plaatu pont yiy génne mbir yi, plomb biy génn ci soudure post yi Separatër bi dafa yàqu ndax plating, impact wala selul bu nëbbu
Courant défaut externe prospective (klaas 48 V) Kawe; Resistance bi ci biir selil bi ak lëkkaloo bi Selul DCIR yuñ mëna méngale wala yu gëna kawe - yu woyof- dañuy yokk, duñu wàññi, collu bi
Aar elektronik buñ tabax ci - Darra; aar ci biti rekk la Detection BMS ak etape de commutation, boole ci fuse bi
teknisien bi mën na gis njuumte Voltage selul bi ak gravite bi dañuy wane selul bu gàtt bi ci saasi Amul hidrometre; gis-gis bi a ngi aju ci selil BMS - duggal woltaas
Loraange gaz ci sarse bu jaar yoon Evolusioŋu hidrogen; ventilaasioŋ ak saytu tàkk-tàkk fàww Amul hydrogen buñy faral di def; gaz ventilé ci jamonoy tàngoor kese
Njexitali ab njuumte buñu leeralul asid buy seey, rupture ci keesu, yàqu-yàqu termik Ventilation cellulaire ak mëna daw termik ak risku tasaaroo
Jëfandikoowaat njuumte ci Post- Benn selil bu gàtt mën nañu ko wecci yenn saa yi Dafay laaj ñu jàngat niveau selil-; wecci module lu bari la

 

Njexital ci jëf mooy doxalin. Soppi litium dafay dindi rond hydromètre bi ba noppi wecci ko ak rond done. Liggéeyu toppatoo bi ñuy jëfandikoo ngir saytu gravite spécifique ci selil bu nekk dafa wara nekk exportation periodique ci selil BMS -tasaaroo voltage ak done decharge boppam - luko moy flotte bi dafay ñàkk benn chaine de avertissement bu teel - ngir ab fault interne, te kenn duko seetlu ba a.

 

Dimensionement ak saytu fuse DC ci ñeenti jéego

 

Lii mooy xayma biy soppi reklamaasioŋu njaay ci leeral buñ mëna saytu. Dafay tàmbalee ci këyitu done ci diir bu mat fukki simili.

 

Jéego Luñu wara xayma misaal biñ liggéey (16S LiFePO4, 460 A wéy)
1. Courant de court- Isc ≈ Voc ÷ (Rselul yi + Rlëkkaloo + Rfiil) 54.4 V ÷ 6–11 mΩ ≈ 5,000–9,000 A
2. Njàngat bu wéy Decharge bi gëna mag biy wéy × 1.25–1.5, xaaj ko ak facteur derating bu 0.8–0.9 460 × 1,35 ÷ 0,85 ≈ 730 A → dayo standard bi ci topp
3. Kàttanu dindi ak voltage DC Dindi kàttan ci kaw Jéego 1 ak marge; voltage nominal dafa wara nekk nominal DC ci wala ci kaw voltage charge max Lu ëpp 9 kA; DC nominal Lu ëpp wala lu tollu ci 58.4 V, nekkul 51.2 V nominal
4. Koordinaasioŋ I2t Fuse bi dafay dindi lépp ci suufu busbar yi, onglet selil yi ak conector yi; ci kaw let- ci bépp aparey bu wara njëkka ubbeeku Tegtaleel courbe fuse bi ak onglet cellulaire bi ak done yiy muñ conector bi

 

Ci Jéego 1.Valeur yiñ bind ci kaw dañuy màndargaal jubluwaay kese. Fukk ak juróomi selul prismatik yu mag ci DCIR buñ siiwal bu 0.3–0.5 mΩ dañuy joxe 4.8–8 mΩ; busbars, konektër ak fiil yokk lu tollu ci 1-3 mΩ. Benn pack 80 V (24S) ak selil DCIR yu gëna ndaw - dafay faral di wàcci ci 10,000 A. Wecci DCIR bi ci këyitu selil bi balaa ngay leeral dara.

 

Ci 3 eelu jéego bi.Ñaari xëcc yu wuute, te ñoom ñaar ñu ngi ñàkk. Benn aparey bu am note AC- dafay sukkandiku ci courant biy jàll zero ñaari yoon ci cycle bu nekk ngir fay arc bi; batëri du joxe zero cross, kon AC- kese nekkul benn note fii.

 

Dawal ñeenti jéego yii48V 412Ah yegg ci pack kamioŋte dafay wane ci saasi ndax aar biñ wax dafay bàyyi bopp wala toog ci catu. Fàww geometri luwaas bi wala harnais bi fi nekk di forse jëmmal bu amul-standard,architecture pack personnalisé ak aplikaasioŋ -fuse ak dimensionnement contacteurmoo gëna set gëna wàññi njëgu paketu stock.

 

DC fuse and busbar arrangement inside a 48V LiFePO4 motive battery pack

 

-Firnde test circuit bu gàtt laata ngay jënd

 

Ñatti këyit dañu yor firndeg -circuit bu gàtt. Laajteel ñett ñi yépp ci nimero rapoor bi, nga xool ndax model bi ci sertifikaa bi mooy model bi ñuy joxe.

 

Tolluwaay bu jaar yoon - anam test sircuit bu gàtt Critère jàll Limu muurul
UN 38.3, Test T.5 (yobbu) Dakkal ci 55 ± 2 degre, gàtt ci résistance externe ci suufu 0.1 Ω, tëye benn waxtu ginaaw bi tàngoor wi delloo ci 55 ± 2 degre Tàngoor wi ci biti Lu néew wala lu tollu ci 170 degre ; amul benn demontage, rupture wala lakk ci diiru test bi ak ci diiru 6 waxtu ci ganaw. Fuse wala vent mën nañu ko jëfandikoo Circuit bu gàtt bi ci biir; selil-ba-tasaaroo selil; ci-sarwis
IEC 62619 (usine, boole ci chariot élévateurs ak AGVs) Circuit bu gàtt ci biti ci selil bi, ci module bi ak ci sistem bi, boole ci jàngat ci jëmmal ci biir -circuit bu gàtt Tàngooru kaw suuf si Lu néew wala lu tollu ci 150 degre ; amul lakk wala kalaate; tasaaro bi nekk ci niveau sistem bi Màrku dugg ci marse bi; sarseer bi ak oto bi -
UL 2580 (limu niveau sistem-) Circuit bu gàtt ci wetu exposition thermique, impact mekanik ak yëngu ci niveau pack ak module Amul lakk, kalaate wala exposition ci cër yu am loraange ci anam yu ñu natt Lépp lu nekk ci biti model bi ak klaas voltage biñ bind ci sertifikaa bi

 

Fiir bi ci ñatteelu rang bi mooy scope. Sàrtifikaa niveau cellulaire- bu bawoo ci furnisër cellulaire bi bokkul ak limu pack yi, te sertifikaa biy wax ci benn classe voltage du muur yeneen yi. Testu dem bi ak dikk bi yépp:Téere UNECE ci wàllu test ak sàrt, pàcc 38.3.

 

Line RFQ buñu mëna liggéey:"Joxeel UN 38.3 T.5 ak IEC 62619 rapoor ci test yu gàtt yi ci biti, boole ci nimero fichier UL 2580, ngir model bi gëna jub, voltage bi ak kàttan biñ wax, boole ci bis bi rapoor bi ak labo bi ko joxe."Su benn ci ñett ñi delloo di wax beneen nimero model, loolu mooy tontu bi. Test sircuit bu gàtt - benn wàll la ci fichier compliance bu gëna mag -UL, CE ak IEC nataal bu mat sëkk ngir pack usine yidafay wane ban màrk mooy jëfandikoo ci ban marse.

 

Field Sequence Su Camion biy daw wala Pack bi tëju

 

Plomb-reflex asid - reset ak jéemaat - mooy jéego bu jaarul yoon ci paketu litium. Liggéey ci komànd bii.

 

  1. Bul reset mbaa - tëjaat.Aparey biy dox defna liggéeyam. Re-energize ci ab fault buñu leeralul dina dindi benn couche de protection bi doxoon.
  2. Isoler ci pack bi ak ci sarseer bi.Firndeel isolation ci natt, te bañ ci position commutateur - contacteur buñ soudé dafay nuru bu ubbeeku ci biti.
  3. Saytu tàngooru kaw gi balaa ngay ubbi dara.Nataalu tàngoor wala jàng bu amul -kontakt ci biir boîtier bi. Bépp zone bu tàng, newwi wala xetu vent dafay tekki taxaw, dindi bay bi, nga jàppee ko ni xew-xew bu tàng buy màgg.
  4. Lis BMS fault log balaa nga koy fomp.Kodu njuumte, tampoŋu waxtu, courant ci tukki bi ak nataalu voltage selil bu nekk ñooy firnde yépp. Buñu ko leeralee, diagnostic bi dafay nekk xalaat.
  5. Saytu bu baax yoon wi ci biti.Kanamu lëkkalekaay bi, fiil bi dafay jaar ci bepp catu tegukaay bi ak pince bi, ci suufu pack bi, ak harnais bi ci wetu kamioŋ bi. Fault yu bari ñu ngi koy gis ci ay simili yu néew.
  6. Saytu ak pack bi amul kuuraŋ.Kontinuite ak bañaale isolation diggante conducteurs ak boîtier, ci voltage test bi defarkatu pack bi wax - megger bu 1,000 V buñ def ci BMS dina ko yàq.
  7. Deel nekk ci quarantaine 24 waxtu balaa ngay jël benn dogal.Gaareel pack bi ci barab bu -dul lakk, am bayaal bu ubbeeku te nga bind ci voltage sircuit bi ci ndoorte ak ci njeexte palanteer bi. Drift voltage ci diir boobu dafay wane ab fault interne buñu inspection externe du gis.

 

Benn jubbantiku bu jara wax bu leer, ndax xalaat bu wuute bi dafa tasaaroo fu nekk: ngir litium-ionpack, boole ci LiFePO4, ndox mu bari mooy seddal ak dindi medium bi war. Agent Class D ñu ngi ko defaree litiumweñte duñu tontu bu jaar yoon ci lakk buy tàkk ci pack lithium{0}}ion. Firndelal sa jegewaale ak kilifay pompie yi ci dëkk bi ak tegtali tontub jafe-jafe yi defarkat bi joxe, waajal diko saytu lu yàgg - ab pack mën na -taal ay waxtu ginaaw bimu feeñee ni dafa fay - te nga méngale tontu bi yépp akSite-niveau kaaraange lakk ngir pack litiumbalaa musiba, du ci jamonoy musiba.

 

Ndax Pack bi mën na dellu ci liggéey bi?

 

Lii mooy dogal bi fault log bi am ngir jàppale, te dafay xaaj bu baax ci barabu fault bi.

 

Fault bu biti, fuse bi moo ko dindi, amul siñaale termik.Dañu koy defaraat Wecci fuse bi ak nimero pièce bu nuróo - musul am nomination bu gëna kawe - defar conducteur bi wala conecteur bi yàqu, xool bu baax resistance isolation bi, xool bu baax ndax contacteur bi soudéwul, nga xool ndax selul -voltage spread bi méngoo na ak pre-fault baseline bi. Ginaaw loolu nga def benn cycle decharge buñuy saytu balaa nga koy delloo ci piscine swap bi.

 

Bépp firnde buy wane ci biir selil.Mënu ñu ko defaraat ci niveau site bi. Li koy màndargaal mooy selul-voltage outlier budul jeex, self-decharge buñ mëna natt ci diiru palanteer quarantaine bi, wala tàngoor wuy yokk bu amul benn sabab bu bawoo ci biti. Yonneel pack bi defarkat bi wala ab naataango bu xarañ ci serwiis batëri ngir ñu xool ni selil bi - tollu. Benn selil bu am benn njuumte ci biir, marge bi dafa wàññeeku ba fàww, ak lépp lumu mëna jàng ci multimetre bi ci ganaw.

 

Laaj yi ñuy faral di laaj

naka ngay saytu batëri chariot élévateur ndax ab court-circuit?

Dindi kuuraŋ ci pack bi, ba noppi nga natt resistance isolation bi ci digganté conducteur bu nekk ak boîtier bi, boole ci continuité ci conducteur yi wara isolé. Jëfandikool voltage test bi defarkatu pack bi wax - megger bu 500–1,000 V dina yàq aparey elektronik BMS. Ci kaw paketu litium, selil BMS -journal voltage bi mooy gëna baax ci biir -detektëru njuumte ci bépp jumtukaay buñuy jëfandikoo ci loxo, ndax dafay jàpp derivation bi test bi ci biti mënu ko gis.

Ndax BMS dafay musal boppam ci court-circuit?

Déedet. BMS dafay gis njuumte gi ba noppi digal ñu ubbi etapu kommutaasioŋ bi, lu bari ci ay téemeeri mikrosegond yu néew, waaye etapu MOSFET bi wala contacteer bu mag bi mënul dagg ay junni ampere. Fuse DC mooy dagg. Benn xeetu pack buy lim aaru BMS waaye amul fuse buy dog ​​ci voltage DC pack amna chaîne de protection bu matt.

Ndax batëri chariot élévateur litium mën na tàkk su amee court-circuit?

Waaw, waaye yoon wi dafa am solo. Fault bu bawoo ci biti buñu dindi ci fuse bu tollu ci dayo bu jaar yoon du bari lumuy yegg ci ignition bi. Risku lakk bu dëggu bi mingi aju ci benn njuumte ci biir selil bi, fu benn aparey bu génn mënu ci dara. Loolu moo tax IEC 62619 di sàkku jàngat ci biir sircuit bu gàtt ak saytu tasaaroo selil ci niveau sistem - te loolu moo tax rapoor boobu, du sertifikaa dem bi, mooy li ñu wara laaj.

Ndax mën nañu reset diisnant bi ginaaw bi batëri chariot élévateur bi jeexee?

Deet. Reset balaa ñuy gis fault bi re-energize yoonu fault bi te mën na soppi xew-xew biñ tëye ci pack bu yàqu. Aparey aar buy dox lu bari yoon dafay wane ab njuumte budul jeex. Isoler, lire BMS log balaa ngay ko fomp, xool yoon wi ci biti, te -renergize rek ginaaw buñu xamee sabab bi ba noppi saafara ko.

Ndax paketu litium moo gëna gaawa gàtt batëri plomb-asid biñ wecci?

Du gëna mëna wuute -. Risku njuumte ci biti mën nañu ko méngale, te fuse yi ak BMS yi ñoo koy jëfandikoo, batëri plomb-asid yi amul benn. Liy soppiku mooy mën nañu ko gis: bu amul hydromètre, ab njuumte ci biir mën nañu ko gis ci selil BMS-done voltage. Flotte yiy soppi te duñu yokk benn done-review routine dañuy ñàkk seen àrtu bu teel.

Yonnee nga laaj